Using critical numbers in the problem of identifying an unknown substance |
Nazarov V. G. |
2024, issue 2, P. 235-251 DOI: https://doi.org/10.47910/FEMJ202421 |
Abstract |
The problem of identifying the chemical composition of a homogeneous medium is considered based on the available approximate data on the values of the attenuation coefficient of X-ray radiation in this medium for a finite set of energies. It is assumed that the medium is one of the substances included in a predetermined finite set $M$. For each substance of the set $M$, the exact values of the attenuation coefficient are known for all energies from a predetermined finite set of energies $E_1, … ,E_N$ from the interval ${[0.001 – 20]}$ MeV. The data on the attenuation coefficients of the medium are known with a given error. The concept of a critical number for a pair of substances and energy is introduced. At the first stage of solving the problem, the set of all critical numbers for all possible pairs of substances from the set $M$ and all the energies used is found. After that, the characteristics of the set of all critical numbers that are necessary for solving the problem are studied. Next, for each energy $E_k$, a set of substances close in value of the attenuation coefficient to the substance of the unknown medium is constructed. Then, from the resulting family of sets, the substance most suitable as a solution to the identification problem is selected. The formulation of the problem is considered justified in the problems of customs control and in medical tomography. The issue of the uniqueness of the solution to the identification problem is considered. Examples of calculations for a set of specific substances are given using some results of previously performed studies. |
Keywords: numerical simulation, continuum radiography, identification of the chemical composition of a substance, accuracy of calculations. |
Download the article (PDF-file) |
References |
[1] Osama Mhmood Hamed Ahmed, YuShou Song, Zhaoyang Xie, “Material Identification Approach Based on the Counting Technique and Beam Hardening Correction under Industrial X-ray Computed Tomography: A Simulation Study.”, Brazilian Journal of Physics, 52:26, (2022). [2] Yokhana V. S. K., Arhatari B. D., Abbey B., “Materials Separation via the Matrix Method Employing Energy-Discriminating X-ray Detection”, Appl. Sci., 12:3198, (2022). [3] Komarskiy A., Korzhenevskiy S., Ponomarev A., Chepusov A., “Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources”, Sensors, 23:4393, (2023). [4] Osipov S. P., Udod V. A., Wang Yanzhao, “Identification of Materials in X-Ray Inspections of Objects by the Dual-Energy Method”, Russian Journal of Nondestructive Testing, 53:8, (2017), 568–587. [5] Osipov S. P., Chakhlov S. V., Batranin A. V, Osipov O. S, “Theoretical study of a simplified implementation model of a dual-energy technique for computed tomography”, NDT & E International, 98, (2018). [6] Osipov S. P., Temnik A. K., Chaklov S. V., “The effects of physical factors on the quality of the dual high-energy identification of the material of an inspected object”, Defektoskopiya, 53:8, (2014). [7] Berger M. J., Hubbell J. H., Seltzer S. M., Chang J., XCOM: Photon Cross Section Database, National Institute of Standards and Technology, Gaithersburg, 2005. [8] Nazarov V. G., Prokhorov I. V., Yarovenko I. P., “Identification of an Unknown Substance by the Methods of Multi-Energy Pulse X-ray Tomography”, Mathematics, 11, (2023). |